Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Olympus |
Weight | 1.68 kg (3.72 lb),including lithium-ion battery |
Dimension | 236 mm x 167 mm x 70 mm (9.3 in. x 6.57 in. x 2.76 in.) |
Display Type | Full VGA (640 x 480 pixels) transflective color LCD |
Model Number | Magna-Mike 8600 |
Keypad | English,Japanese,Chinese,International |
Data Storage | Onboard and removable 2 GB MicroSD card |
Battery Life | 16 h (lithium-ion) (Optional) |
Power Requirements | AC Mains 100 VAC to120 VAC,200 VAC to 240 VAC |
Display Dimensions | 117 mm x 89 mm,146 mm (4.62 in. x 3.49 in.,5.76 in.) |
Display Update Rate | 4,8,16 and 20 Hz |
Operation Temperature | 10 Deg C to 50 Deg C (14 Deg F to 122 Deg F) |
Additional Information:
Product Details:
Model Number | XL2 |
Data Memory | 64 MB internal system memory/128 MB internal user storage |
Data Storage | Internal greater-than 10,000 readings with spectra |
Data Transfer | USB, Bluetooth and RS-232 serial communication |
Description | Niton XL2 XRF Analyzer |
Detector Type | High-performance semiconductor |
Display Type | Fixed angle, color, touch-screen display |
Height | 4 Inch, 100 mm |
Length | 10.25 Inch, 256 mm |
Width | 11 Inch. 275 mm |
Optional Accessories | Portable test stand; Stationary (bench-top) stand; Mobile test stand; Welding mask; Soil testing gua |
Power Consumption | 100 microampere |
Tube Type | Aganode 45 kV maximum, 80 microampere maximum |
Weight | 3.0 lb., 5.8 oz., 1.53 kg |
Voltage | 45 kV |
Dimensions | 10.25 x 11 x 4 in. (256 x 275 x 100 mm) |
Product Details:
Minimum Order Quantity | 1 Piece |
Usage/Application | Industrial Use |
Brand | Olympus |
Model Name/Number | Vanta Element |
Warranty | 1 Year |
Calibration | Yes |
Weight With Battery | 1.5 kg (3.25 lbs) without battery |
Display Type | Digital |
Dimensions | 260 x 240 x 90 mm (10.25 x 9.5 x 3.5 in.) |
Environmental Temperature Range | -10 Deg C to 50 Deg C (14 Deg F to 122 Deg F) |
Processing Electronics | 530 MHz CPU with integrated FPU with 128 MB RAM; Proprietary Olympus Digital Pulse Processor (DPP) |
Power | Rechargeable Li-ion battery; Hot-swap maintains analyzer power during battery charge |
Data Display | 32 bit Color QVGA resolution, Blanview transmissive backlit touch screen; 57 x 73 mm (2.25 x 2.9 in. |
Data Storage | 1 GB microSD (stores - 75,000 readings) |
Data Transfer | USB, Bluetooth |
Additional Information:
Product Details:
Brand | SKF |
Usage/Application | Laboratory |
Suitable Oil Types | Mineral and Synthetic Oils |
Repeatability | Better than 95% |
Read Out | Green/Red grading + Numerical value (-999 to 999) |
Battery | 9V Alkaline IEC 6LR61 |
Battery Lifetime | Greater Than 150 hours or 3 000 tests |
Dimension | Instrument 250 x 95 x 32 mm (9.8 x 3.7 x 1.3 in.) |
Weight | Instrument 385 g (14 oz) |
Product Details:
Display Type | Digital |
Operating Temperature | 350 Deg C |
Operating Pressure | 25 Kg/Cm2 |
Line Size | 15 NB to 150 NB |
Accuracy | +/-0.5% |
Brand | Kent |
Flow Range | 0.1 to 350 M3/hr |
Product Details:
Display Type | LED |
Brand | Alfa |
Current | 6 A |
Usage/Application | Screw Air Compressor |
Size | 145 x115x71 mm |
Digital Outputs | 10 |
Ambient Temperature | 2 Deg (PT100/PT1000) |
Air Pressure | 2 (4-20mA) |
Main Box Hole Size | 135X105mm |
Monitor Size | 164x102x54mm |
Monitor Hole Size | 156.8x93mm |
Screen Size | 33x66mm |
Material | Plastic |
Power | 16-24V/15W |
Digital Input | 8 |
Phase | Single |
Terminal | Screw (Socket or screw ) |
Product Details:
Material | Mild Steel |
Usage/Application | Laboratory |
Color | Black |
Packaging Type | Box |
Display Type | 1999 counts (3 1/2digits), Large LCD |
Brand | Kyoritsu |
Dimension | 167(L)x186(W)x89(D)mm |
Insulation Resistance | 50 milliohm or more / 1000V |
Measuring Range | 80V to 450V 50/60Hz |
Accuracy | 1%rdg +- 3dgt (Trip Time) |
Weight | Approx. 965g (including batteries) |
Power Source | DC 12V / R6(AA)(1.5V) x 8 |
Test Current | 15/30/50/100mA |
Rated Voltage | 100V to 400 V +-10% |
Operating Temperature | 0C - 40 Deg C |
Relative Humidity | 85% (no condensation) |
Storage temperature | -20 C - 60 Deg C relative humidity 85% (no condensation) |
Product Details:
Model Name/Number | AM-P-AL |
Brand | Aquasol |
Accuracy | +- 1% |
Dimension | 183 x 37 x 37 mm |
Weight | 90 g |
Ph Range | 0.00 to 14.00 |
Atc Ph | 0 - 60 Deg C |
Resolution | 0.01 pH |
TDS Range | 1 to 19999 PPM |
TDS Resolution | 1PPM |
TDS Accuracy | +- 2% |
Product Details:
Minimum Order Quantity | 5 Number |
Country of Origin | Made in India |
Additional Information:
Product Details:
Model Name/Number | PA201 1ch |
Frequency Range | 0.5 - 16kHz(3dB) or 0.5 - 20kHz(3dB) |
Temperature | -10 Deg to +50 Deg |
Brand | SV |
AD Converter | 24 Bit |
Input Channel | 1 - 4 Channel, Tacho |
Sensor Type | IEPE, AC, RPM, IR Temperature Sensor |
Sampling Frequency | 32,768Hz or 51,200Hz |
Input Range | +-5V(peak) or +-2.5V(peak) |
Input Signal Gain | 2, 4, 8, 16, 32, 64 |
SNR | 100dB More |
Dynamic Range | 17 - 134dB (50mV/Pa x 10Gain) |
High Pass Filter | 1Hz, 5Hz, 10Hz |
Product Details:
Minimum Order Quantity | 1 Piece |
Display | Digital |
Brand | Alfa |
Accuracy | +/- 2% F.S.D. |
Rangeability | 101 |
Output | 4 to 20 mA DC |
Minimum Conductivity | 10us |
Max Pressure | 10 kg cm2 |
Environment Temperature | -5 to 55 deg c |
A flow meter is a device used to measure the volume or mass of a gas or liquid. Flow meters are referred to by many names, such as flow gauge, flow indicator, liquid meter, flow rate sensor, etc. depending on the particular industry. However, they all measure flow. Open channels, like rivers or streams, may be measured with flow meters. Or more frequently, the most utility from a flow meter and the greatest variety of flow meters focus on measuring gasses and liquids in a pipe. Improving the precision, accuracy, and resolution of fluid measurement are the greatest benefits of the best flow meters.
Product Details:
Minimum Order Quantity | 1 Unit |
Usage/Application | Industrial |
Material | SS |
Temperature Accuracy | +/-01 degree C |
Volume | 5ml, 7 ml, 10ml, 20 m, 20 ml |
Product Details:
Minimum Order Quantity | 1 Piece |
Machine Type | XRF Analyzer |
Warranty | 12 |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Number |
Automation Grade | Automatic |
Usage/Application | Grains |
Display Type | Digital |
Language | English |
Model | MB120 |
Brand | Ohaus |
Automatic Grade | Automatic |
Display Type | Digital |
Maximum capacity (Gram) | 120g |
Pan Size (millimetre) | 90mm |
Application | Laboratory Use |
Capacity | 120g |
Display | 109 mm, QVGA, TFT, Touch screen |
Minimum Order Quantity | 1 |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Number |
Application Media | Oil or Diesel |
Brand | KENT |
Additional Information:
Product Details:
Application Media | OIL |
Brand | KENT |
Product Details:
Model Name/Number | Operation Power cord (included) Communication RS232 with GLP/GMP data output, USB Host and USB De |
Product Details:
Minimum Order Quantity | 1 Number |
Usage/Application | Industrial |
Number Of Channels | 6 Channels |
Brand | Alfa |
Material | Aluminium Alloy |
Shape | Rectangular |
Temperature Range | -30 to 150 deg C |
Temperature Accuracy | +/-01 degree C |
Stirrer Rotation | Clockwise & Anti-clockwise (Both) |
Additional Information:
Product Details:
Brand | Fluke |
Temperature Range | -30 C to 500 Deg C (-22 to 932 Deg F) |
Color | Yellow |
Accuracy | +-1.5 DegreeC or +-1.5% of reading,whichever is greater |
Battery Life | 10 hours with laser and backlight on |
Display Resolution | 0.1 Deg C (0.2 Deg F) |
Emissivity | 0.10 to 1.00 |
Power | AA battery |
Response Time | Less than 500 ms (95% of reading) |
Size/Dimension | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) |
Weight | 255 g (8.99 oz) |
Spectral Response | 8 to 14 microns |
Optical Resolution | 101 (calculated at 90% energy) |
Repeatability of Readings | +- 0.8% of reading or Less than +- 1.0 Deg C (2 Deg F),whichever is greater |
Operating Temperature | 0 to 50 Deg C (32 to 122 Deg F) |
Storage Temperature | -20 to 60 Deg C (-4 to 140 Deg F),(without battery) |
Operating Humidity | 10% to 90% RH non-condensing at 30 Deg C (86 Deg F) |
Operating Altitude | 2000 meters above mean sea level |
Storage Altitude | 12,000 meters above mean sea level |
IP Rating | IP 54 per IEC 60529 |
Drop Test | 3 meters |
Vibration and shock | IEC 68-2-6 2.5 g,10 to 200 Hz,IEC 68-2-27,50 g,11 ms |
EMC | EN 61326-12006 EN 61326-22006 |
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | PSA-311 |
Brand | Lutron |
Display | LCD, size 20 mm x 28 mm |
Sampling Time | Approx. 0.8 second. |
Operating Temperature | 0 to 50 Deg C ( 32 to 140 Deg F ). |
Operating Humidity | Less than 80% RH. |
Power Consumption | Approx. 5.7 mA |
Weight | 171 g/0.38 LB. |
Dimension | 190 x 40 x 40 mm ( 7.5 x 1.6 x 1.6 inch ). |
Resolution | 0.01 % salt. |
Data Hold | Freeze the display reading. |
Power Supply | DC 1.5V battery ( UM-4/AAA ) x 4 PCs |
Product Details:
Type | Rigid |
Brand | ALFA |
Material | Aluminium |
Process Connection | Flange DN100 |
Non Contact Type Medium | Crude Oil |
Operating Temperature | -5 Deg C to +50 Deg C |
Viscosity | 6.37 cst (50 Deg C) |
Pressure Rating | PN16 |
Density | 0.8739g/ml (15 Deg C) |
Signal No One | 18 meter of oil level to stop the feeding pump |
Signal No Two | 12 meter of oil level to give alarm to operator |
Power Supply | 24V DC |
Product Details:
Usage/Application | Compression Tester Flex Drive |
Display Type | Analog |
Brand | TRISCO |
Adaptor Size | 14 mm/18 mm |
Pressure | 0-300 psi, 21 kg/cm, 21 bar and 2100 kpa |
Packaging Type | Box |
Product Details:
Brand | Alfa |
Material | MS |
Display Type | Digital |
Voltage | 220 V |
Phase | Single |
Product Details:
Accuracy | +-0.05% |
Resolution | 0.01% |
Usage/Application | Citrus |
Kinds of acid | Citric Acid |
Measuring Ranges | 0.00-3.50 % |
Power Source | 9V Battery 1ea |
Dimensions | 154(W) x 108(L) x 43(H)mm |
Gross Weight | Approx. 1Kg |
Product Details:
Brand | Siemens |
Accuracy | EN1434 Class 3,+- 0.5 |
Model Number | SITRANS FUE950 |
Display | 8-digit LCD display with associated pictograms/symbols |
Enclosure | IP54 (in accordance with IEC 529) |
Power Supply | Battery (3.6V Lithium D-cell type),230 V AC,24 V AC |
Temperature Input | From -20 to 190 Deg C (-4 to 374 Deg F) |
Ambient Temperature | From 0 to 55 Deg C (32 to 131 Deg F) |
Additional Information:
Product Details:
Type Of Breath Alcohol Analyzer | Digital |
Usage/Application | Laboratory |
Brand | Alfa |
Display | Digital |
Accuracy | +/-0.015% BAC at 0.05% BAC |
Type Of Mouthpiece | Replaceable |
Power Source | Battery |
Blowing Time | 10 Seconds |
Weights | 80 gram |
Alarming Level | 0.05 BAC%; 0.25 mg/L; 50mg/100mL |
Working Voltage | DC 4.5 V (3 x AAA) Batteries |
Product Details:
Usage/Application | Laboratory, Blood Bank |
Brand | Alfa |
Material | Metal |
Shape | Rectangular |
Capacity | 500 ml Bag |
Accuracy | 100% |
Clamping Force | 20N |
Electronic Plasma Expresser is designed for automatic separation of Blood Components from the Blood Bag. It is semiautomatic equipment to separate blood in to red cells and plasma.
Salient Features:
We are engaged in offering Flameproof LED Lamps & Lights in Different Wattages
We offer :-
FLP LED Tube Light Fittings - 1x20W / 2x20w
FLP LED Wellglass Fittings from 30w to 400W
FLP Flood LIght Fittings In LED
FLP LED Bulkhead Fittings in Different Wattages
FLP Cleanroom LED Fittings from 20W to 200W
Product Details:
Brand | KENT |
Product Details:
Minimum Order Quantity | 1 Piece |
Usage/Application | Industrial |
Brand | Alfa |
Material | Steel |
Accuracy | 1 % |
Temperature Range | -50 to 150 degc, -50 to 120 deg C, -20 to 70 deg C |
Sampling Time | 5 sec/ 10 sec/ 30 sec |
Resolution | 0.1 deg C |
Pipe Length | Up to 25 mm |
Pipe Outer Diameter | 3 mm to 14 mm |
Range of Temperature Gauges:
Application:
Product Details:
Usage/Application | Temperature Measurement |
Brand | Alfa |
Material | SS |
Accuracy | 1.5% |
Temperature Range | 0 - 1300 degree C |
Ambient Temperature | 20+/-15 degree C |
Theory | Temperature Controller |
Test Voltage | 500+/-50V |
Protection Tube | 316L |
Product Details:
Model Name/Number | SALOMIX SLF agitator |
Power | 2.2 - 110 kW / 3 - 150 HP |
Performance Range | SALOMIX SL/ST agitators have a wide and comprehensive hydraulic coverage which enable their use in |
Stock Concentration | Up to 6 % |
Propeller Diameter | 500 mm - 1 650 mm / 20 - 65 Inch |
Maximum Speed of Rotation | Up to 500 rpm |
Temperatures | Up to 180 Deg C / 355 Deg F |
Product Details:
Material | Mild Steel |
Size | M6 To M125 |
Brand | Alfa |
Surface Finishing | Polished |
Usage/Application | Construction |
Packing Type | Jute Bag |
Delivery Scopetesto 608-H1 digital thermohygrometer including battery.
RTD’s are temperature measuring sensors which use the resistance /temperature relationship of material to measure the temperature of a body. RTDs have higher accuracy and stability as compared to Thermocouples usually in the below 600 °C range. Resistance temperature sensors are composed of realizing material generally Copper, Nickel, or platinum, which shows resistance at a specific temperature. If we want to measure temperature with high accuracy, an RTD is an ideal solution, as it has good linear characteristics over a wide range of temperatures.
Resistance Vs. Temperature Relationship:
The Resistance versus Temperature relationship is expressed as the measure of progress in the resistance of the component per degree change in temperature. This relative change in resistance is called the Temperature Coefficient of Resistance (α) and this remains nearly constant throughout the temperature range of the sensor. Platinum is a highly preferred material for RTD sensors as not at all like different components it has a profoundly straight Resistance – Temperature relationship which is repeatable inside a wide temperature range. This linear temperature ranges from (-272.5) °C – (961.78) °C. It is also preferred due to its chemical inertness which makes it ideal to use in any environment. The sensors made for the International Temperature Scale standard (ITS-90) are of Platinum sensors. Copper additionally has a decent straight Resistance – Temperature relationship however it oxidizes over 150 °C, which makes it questionable for higher temperatures. Nickel shows a Non-Linear relationship above 300 °C which limits its temperature range.
The resistance at 0°C is called R0 and it is a significant boundary to be characterized. The most commonly used RTD element is platinum with a resistance of 100 Ω at 0°C. Hence named as Pt 100 Platinum RTD are appropriate for temperature range - 200 to 850°C. Normally, Industrial RTDs are used at a temperature range up to 400°C.
The direct estimation of resistance versus temperature is taken between 0 °C – 100 °C. α = (R100 – R0)/(R0 x ΔT)
Where
R100 is the resistance of the sensor at 100 °C
R0 is the resistance of the sensor at 0 °C
ΔT is the temperature distinction
Pure Platinum has α= 0.003926 Ω/(Ω•°C) for 0 – 100 °C range.
Be that as it may, the worthy worth indicated by IEC 60751 and ASTM E-1137 Standards is α = 0.00385 Ω/(Ω•°C). The estimation of α is shifted by a cycle called doping in which contaminations are combined into the sub-atomic grid of Platinum in a controlled style.
Resistance temperature detectors ( RTD's ) - Components are additionally accessible with resistance 200, 500, and 1000 Ω at 0°C. Such kind of RTDs is known as PT200, PT500, and PT1000 individually. The temperature coefficients of these sorts are additionally equivalent to the PT100, yet these give higher resistance change per degree Celsius which in turn gives the higher resolution.