Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Olympus |
Weight | 1.68 kg (3.72 lb),including lithium-ion battery |
Dimension | 236 mm x 167 mm x 70 mm (9.3 in. x 6.57 in. x 2.76 in.) |
Display Type | Full VGA (640 x 480 pixels) transflective color LCD |
Model Number | Magna-Mike 8600 |
Keypad | English,Japanese,Chinese,International |
Data Storage | Onboard and removable 2 GB MicroSD card |
Battery Life | 16 h (lithium-ion) (Optional) |
Power Requirements | AC Mains 100 VAC to120 VAC,200 VAC to 240 VAC |
Display Dimensions | 117 mm x 89 mm,146 mm (4.62 in. x 3.49 in.,5.76 in.) |
Display Update Rate | 4,8,16 and 20 Hz |
Operation Temperature | 10 Deg C to 50 Deg C (14 Deg F to 122 Deg F) |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Usage/Application | Industrial Use |
Brand | Olympus |
Model Name/Number | Vanta Element |
Warranty | 1 Year |
Calibration | Yes |
Weight With Battery | 1.5 kg (3.25 lbs) without battery |
Display Type | Digital |
Dimensions | 260 x 240 x 90 mm (10.25 x 9.5 x 3.5 in.) |
Environmental Temperature Range | -10 Deg C to 50 Deg C (14 Deg F to 122 Deg F) |
Processing Electronics | 530 MHz CPU with integrated FPU with 128 MB RAM; Proprietary Olympus Digital Pulse Processor (DPP) |
Power | Rechargeable Li-ion battery; Hot-swap maintains analyzer power during battery charge |
Data Display | 32 bit Color QVGA resolution, Blanview transmissive backlit touch screen; 57 x 73 mm (2.25 x 2.9 in. |
Data Storage | 1 GB microSD (stores - 75,000 readings) |
Data Transfer | USB, Bluetooth |
Additional Information:
Product Details:
Brand | SKF |
Usage/Application | Laboratory |
Suitable Oil Types | Mineral and Synthetic Oils |
Repeatability | Better than 95% |
Read Out | Green/Red grading + Numerical value (-999 to 999) |
Battery | 9V Alkaline IEC 6LR61 |
Battery Lifetime | Greater Than 150 hours or 3 000 tests |
Dimension | Instrument 250 x 95 x 32 mm (9.8 x 3.7 x 1.3 in.) |
Weight | Instrument 385 g (14 oz) |
Product Details:
Display Type | Digital |
Operating Temperature | 350 Deg C |
Operating Pressure | 25 Kg/Cm2 |
Line Size | 15 NB to 150 NB |
Accuracy | +/-0.5% |
Brand | Kent |
Flow Range | 0.1 to 350 M3/hr |
Product Details:
Model Name/Number | AM-P-AL |
Brand | Aquasol |
Accuracy | +- 1% |
Dimension | 183 x 37 x 37 mm |
Ph Range | 0.00 to 14.00 |
Weight | 90 g |
Atc Ph | 0 - 60 Deg C |
Resolution | 0.01 pH |
TDS Range | 1 to 19999 PPM |
TDS Resolution | 1PPM |
TDS Accuracy | +- 2% |
Product Details:
Type Of Breath Alcohol Analyzer | Digital |
Usage/Application | Laboratory |
Brand | Alfa |
Display | Digital |
Accuracy | +/-0.015% BAC at 0.05% BAC |
Type Of Mouthpiece | Replaceable |
Power Source | Battery |
Blowing Time | 10 Seconds |
Weights | 80 gram |
Alarming Level | 0.05 BAC%; 0.25 mg/L; 50mg/100mL |
Working Voltage | DC 4.5 V (3 x AAA) Batteries |
Product Details:
Minimum Order Quantity | 5 Number |
Country of Origin | Made in India |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Unit |
Usage/Application | Industrial |
Material | SS |
Temperature Accuracy | +/-01 degree C |
Volume | 5ml, 7 ml, 10ml, 20 m, 20 ml |
Product Details:
Model Name/Number | PA201 1ch |
Frequency Range | 0.5 - 16kHz(3dB) or 0.5 - 20kHz(3dB) |
Temperature | -10 Deg to +50 Deg |
Brand | SV |
AD Converter | 24 Bit |
Input Channel | 1 - 4 Channel, Tacho |
Sensor Type | IEPE, AC, RPM, IR Temperature Sensor |
Sampling Frequency | 32,768Hz or 51,200Hz |
Input Range | +-5V(peak) or +-2.5V(peak) |
Input Signal Gain | 2, 4, 8, 16, 32, 64 |
SNR | 100dB More |
Dynamic Range | 17 - 134dB (50mV/Pa x 10Gain) |
High Pass Filter | 1Hz, 5Hz, 10Hz |
Product Details:
Minimum Order Quantity | 1 Piece |
Machine Type | XRF Analyzer |
Warranty | 12 |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Number |
Automation Grade | Automatic |
Usage/Application | Grains |
Display Type | Digital |
Language | English |
Model | MB120 |
Brand | Ohaus |
Automatic Grade | Automatic |
Display Type | Digital |
Maximum capacity (Gram) | 120g |
Pan Size (millimetre) | 90mm |
Application | Laboratory Use |
Capacity | 120g |
Display | 109 mm, QVGA, TFT, Touch screen |
Minimum Order Quantity | 1 |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Number |
Application Media | Oil or Diesel |
Brand | KENT |
Additional Information:
Product Details:
Application Media | OIL |
Brand | KENT |
Machine Type | Handheld XRF Analyzer |
Usage/Application | Elemental Analysis Positive Metal Identification (PMI) |
Model Name/Number | Niton XL2 100G |
Model | NITON XL2 100G |
Application | Industrial Use |
Warranty | 1 year |
Brand | ThermoFisher scientific, Niton |
Detector Type | High-performance semiconductor |
Measurement Time (s) | 15 |
Wi Fi Enable | No |
Connectivity | cable, bluetooth |
Weight With Battery (kg) | 1.53 |
Time To Result (min) | 0.5 |
Display Type | digital |
Software | NDT |
Condition | New |
Usage | Elemental Analysis, Positive Metal Identification |
Type | Handheld XRF Analyzer |
Minimum Order Quantity | 1 Nos |
We are engaged in offering Flameproof LED Lamps & Lights in Different Wattages
We offer :-
FLP LED Tube Light Fittings - 1x20W / 2x20w
FLP LED Wellglass Fittings from 30w to 400W
FLP Flood LIght Fittings In LED
FLP LED Bulkhead Fittings in Different Wattages
FLP Cleanroom LED Fittings from 20W to 200W
Product Details:
Brand | KENT |
Machine Type | Portable |
Model Name/Number | Model 1030 |
Usage/Application | Laboratory Use |
Parameters | 3 to 200 mmol/L |
Voltage | Four AA Alkaline batteries (NEDA 15A, IEC LR6) Typical solid-state, over-current circuit protection |
Minimum Order Quantity | 1 |
Product Details:
Model Name/Number | Operation Power cord (included) Communication RS232 with GLP/GMP data output, USB Host and USB De |
Product Details:
Minimum Order Quantity | 1 Number |
Number Of Channels | 6 Channels |
Usage/Application | Industrial |
Brand | Alfa |
Material | Aluminium Alloy |
Shape | Rectangular |
Temperature Range | -30 to 150 deg C |
Temperature Accuracy | +/-01 degree C |
Stirrer Rotation | Clockwise & Anti-clockwise (Both) |
Additional Information:
Product Details:
Model Number | XL2 |
Data Memory | 64 MB internal system memory/128 MB internal user storage |
Data Storage | Internal greater-than 10,000 readings with spectra |
Data Transfer | USB, Bluetooth and RS-232 serial communication |
Description | Niton XL2 XRF Analyzer |
Detector Type | High-performance semiconductor |
Display Type | Fixed angle, color, touch-screen display |
Height | 4 Inch, 100 mm |
Length | 10.25 Inch, 256 mm |
Width | 11 Inch. 275 mm |
Optional Accessories | Portable test stand; Stationary (bench-top) stand; Mobile test stand; Welding mask; Soil testing gua |
Power Consumption | 100 microampere |
Tube Type | Aganode 45 kV maximum, 80 microampere maximum |
Weight | 3.0 lb., 5.8 oz., 1.53 kg |
Voltage | 45 kV |
Dimensions | 10.25 x 11 x 4 in. (256 x 275 x 100 mm) |
Product Details:
Brand | Fluke |
Temperature Range | -30 C to 500 Deg C (-22 to 932 Deg F) |
Color | Yellow |
Accuracy | +-1.5 DegreeC or +-1.5% of reading,whichever is greater |
Battery Life | 10 hours with laser and backlight on |
Display Resolution | 0.1 Deg C (0.2 Deg F) |
Emissivity | 0.10 to 1.00 |
Power | AA battery |
Response Time | Less than 500 ms (95% of reading) |
Size/Dimension | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) |
Weight | 255 g (8.99 oz) |
Spectral Response | 8 to 14 microns |
Optical Resolution | 101 (calculated at 90% energy) |
Repeatability of Readings | +- 0.8% of reading or Less than +- 1.0 Deg C (2 Deg F),whichever is greater |
Operating Temperature | 0 to 50 Deg C (32 to 122 Deg F) |
Storage Temperature | -20 to 60 Deg C (-4 to 140 Deg F),(without battery) |
Operating Humidity | 10% to 90% RH non-condensing at 30 Deg C (86 Deg F) |
Operating Altitude | 2000 meters above mean sea level |
Storage Altitude | 12,000 meters above mean sea level |
IP Rating | IP 54 per IEC 60529 |
Drop Test | 3 meters |
Vibration and shock | IEC 68-2-6 2.5 g,10 to 200 Hz,IEC 68-2-27,50 g,11 ms |
EMC | EN 61326-12006 EN 61326-22006 |
Product Details:
Minimum Order Quantity | 1 Piece |
Model Name/Number | PSA-311 |
Brand | Lutron |
Display | LCD, size 20 mm x 28 mm |
Sampling Time | Approx. 0.8 second. |
Operating Temperature | 0 to 50 Deg C ( 32 to 140 Deg F ). |
Operating Humidity | Less than 80% RH. |
Power Consumption | Approx. 5.7 mA |
Weight | 171 g/0.38 LB. |
Dimension | 190 x 40 x 40 mm ( 7.5 x 1.6 x 1.6 inch ). |
Resolution | 0.01 % salt. |
Data Hold | Freeze the display reading. |
Power Supply | DC 1.5V battery ( UM-4/AAA ) x 4 PCs |
Product Details:
Type | Rigid |
Brand | ALFA |
Material | Aluminium |
Process Connection | Flange DN100 |
Non Contact Type Medium | Crude Oil |
Operating Temperature | -5 Deg C to +50 Deg C |
Viscosity | 6.37 cst (50 Deg C) |
Pressure Rating | PN16 |
Density | 0.8739g/ml (15 Deg C) |
Signal No One | 18 meter of oil level to stop the feeding pump |
Signal No Two | 12 meter of oil level to give alarm to operator |
Power Supply | 24V DC |
Product Details:
Minimum Order Quantity | 1 Piece |
Usage/Application | Industrial |
Material | Steel |
Accuracy | 1 % |
Temperature Range | -50 to 150 degc, -50 to 120 deg C, -20 to 70 deg C |
Sampling Time | 5 sec/ 10 sec/ 30 sec |
Resolution | 0.1 deg C |
Pipe Length | Up to 25 mm |
Pipe Outer Diameter | 3 mm to 14 mm |
Range of Temperature Gauges:
Application:
Product Details:
Usage/Application | Compression Tester Flex Drive |
Display Type | Analog |
Brand | TRISCO |
Adaptor Size | 14 mm/18 mm |
Pressure | 0-300 psi, 21 kg/cm, 21 bar and 2100 kpa |
Packaging Type | Box |
Product Details:
Brand | Alfa |
Material | MS |
Display Type | Digital |
Voltage | 220 V |
Phase | Single |
Product Details:
Accuracy | +-0.05% |
Resolution | 0.01% |
Usage/Application | Citrus |
Kinds of acid | Citric Acid |
Measuring Ranges | 0.00-3.50 % |
Power Source | 9V Battery 1ea |
Dimensions | 154(W) x 108(L) x 43(H)mm |
Gross Weight | Approx. 1Kg |
Product Details:
Material | Mild Steel |
Usage/Application | Laboratory |
Color | Black |
Packaging Type | Box |
Display Type | 1999 counts (3 1/2digits), Large LCD |
Brand | Kyoritsu |
Dimension | 167(L)x186(W)x89(D)mm |
Insulation Resistance | 50 milliohm or more / 1000V |
Accuracy | 1%rdg +- 3dgt (Trip Time) |
Measuring Range | 80V to 450V 50/60Hz |
Weight | Approx. 965g (including batteries) |
Power Source | DC 12V / R6(AA)(1.5V) x 8 |
Test Current | 15/30/50/100mA |
Rated Voltage | 100V to 400 V +-10% |
Operating Temperature | 0C - 40 Deg C |
Relative Humidity | 85% (no condensation) |
Storage temperature | -20 C - 60 Deg C relative humidity 85% (no condensation) |
Product Details:
Brand | Siemens |
Accuracy | EN1434 Class 3,+- 0.5 |
Model Number | SITRANS FUE950 |
Display | 8-digit LCD display with associated pictograms/symbols |
Enclosure | IP54 (in accordance with IEC 529) |
Power Supply | Battery (3.6V Lithium D-cell type),230 V AC,24 V AC |
Temperature Input | From -20 to 190 Deg C (-4 to 374 Deg F) |
Ambient Temperature | From 0 to 55 Deg C (32 to 131 Deg F) |
Additional Information:
Product Details:
Usage/Application | Laboratory, Blood Bank |
Brand | Alfa |
Material | Metal |
Shape | Rectangular |
Capacity | 500 ml Bag |
Accuracy | 100% |
Clamping Force | 20N |
Electronic Plasma Expresser is designed for automatic separation of Blood Components from the Blood Bag. It is semiautomatic equipment to separate blood in to red cells and plasma.
Salient Features:
Product Details:
Minimum Order Quantity | 1 Piece |
Display | Digital |
Brand | Alfa |
Accuracy | +/- 2% F.S.D. |
Rangeability | 101 |
Output | 4 to 20 mA DC |
Minimum Conductivity | 10us |
Max Pressure | 10 kg cm2 |
Environment Temperature | -5 to 55 deg c |
A flow meter is a device used to measure the volume or mass of a gas or liquid. Flow meters are referred to by many names, such as flow gauge, flow indicator, liquid meter, flow rate sensor, etc. depending on the particular industry. However, they all measure flow. Open channels, like rivers or streams, may be measured with flow meters. Or more frequently, the most utility from a flow meter and the greatest variety of flow meters focus on measuring gasses and liquids in a pipe. Improving the precision, accuracy, and resolution of fluid measurement are the greatest benefits of the best flow meters.
Product Details:
Usage/Application | Temperature Measurement |
Brand | Alfa |
Material | SS |
Accuracy | 1.5% |
Temperature Range | 0 - 1300 degree C |
Ambient Temperature | 20+/-15 degree C |
Theory | Temperature Controller |
Test Voltage | 500+/-50V |
Protection Tube | 316L |
Product Details:
Model Name/Number | SALOMIX SLF agitator |
Power | 2.2 - 110 kW / 3 - 150 HP |
Performance Range | SALOMIX SL/ST agitators have a wide and comprehensive hydraulic coverage which enable their use in |
Stock Concentration | Up to 6 % |
Propeller Diameter | 500 mm - 1 650 mm / 20 - 65 Inch |
Maximum Speed of Rotation | Up to 500 rpm |
Temperatures | Up to 180 Deg C / 355 Deg F |
Product Details:
Material | Mild Steel |
Size | M6 To M125 |
Brand | Alfa |
Surface Finishing | Polished |
Usage/Application | Construction |
Packing Type | Jute Bag |